Features
◆Intelligent two-wire 4-20mA working mode, better anti-interference ability, lossless long-distance signal transmission.
◆Provide high-precision cold-junction compensation, based on the industrial-grade cold-junction temperature compensation range of -40~80℃.
◆Special customized ASSIC circuit with higher integration and better reliability.
◆Fully digital calibration, no movable potentiometer, temperature drift as low as <30ppm.
◆Strengthen EMC anti-jamming design and hardware watchdog, suitable for various industrial environments with harsh electromagnetic environment.
◆Pure digital thermocouple calibration calculation, with higher accuracy, adopting the international temperature standard ITS-90 calculation standard.
◆Intelligent USB/calibration interface, microUSB socket, professional calibration configuration software, calibration is convenient and quick.
◆Professional transmitter calibration software, the software has user version and factory version.
Technical indicators and parameters
voltage |
10~36VDC, 24VDC is recommended. |
Temperature drift coefficient |
<30ppm/°C or .004%FS/1°C (basic range) |
Measuring range |
There are 8 types of thermocouples R, S, T, N, J, K, B, and E, which support full temperature range measurement. Can be configured by PC. |
working environment |
Temperature -40℃~80℃, humidity <85%, dry and non-corrosive environment. |
PC interface |
USB. |
Dimensions |
The diameter is 44mm*22.5mm cylindrical. |
output signal |
Two-wire system 4-20mA, current resolution is about 1.6uA. |
measurement accuracy |
0.2%FS |
Limit current |
Wire break alarm, about 22mA. |
Cold end warming |
-40~80℃ |